Home > Offer to Sell > Paint and Coatings > Building Coating > DIN 4102-1 fire test to building material-classification

DIN 4102-1 fire test to building material-classification

Inquiry
  Post Date: Aug 01,2014
  Expiry Date: Aug 01,2015
  Detailed Description: DIN 4102-1 fire test to building material-classification

Firetc fire test center will provide Germany Standard DIN 4102-1 Fire test to Building Material.

For more detailed information about DIN 4102-1,
Please see: http://www.firetc.net/firetesting/show.php?itemid=663

DIN 4102-1 fire test to building material
> DIN 4102-1 Fire behaviour of building materials and elements Part 1: Classification of building materials Requirements and testing

DIN 4102-1 fire test to building material - Instruction
This standard defines fire behaviour classes for building materials and specifies requirements and test methods for each class

> DIN 4102-1 fire test to building material - Classification
When the material's fire behaviour has been determined in accordance with the standard, it divides into:

> DIN 4102-1: Class A
A1: Materials may be classed as A1 materials if they:
- Pass the test specified according the standard corresponding parts
- meet the requirements for class A2 materials
A2: Materials may be classed as A2 materials if they:
- Pass the test specified according the standard corresponding parts
- Pass the test specified DIN 4102-16

> DIN 4102-1: Class B
B1: All materials, except flooring, may be classed as B1 materials if they
- Withstand the test specified in DIN 4102-16 using the”Brandschacht” apparatus specified in DIN 4102-15
- Meet the requirements for class B2 materials.
B2: Materials may be classed as B2 materials if they
- Pass the test specified according the standard corresponding parts
- Flooring materials may be assigned to material class B2 if they meet at least the requirements for class T-b as in DIN 66081.
B3: Combustible materials which cannot be classed as B1 or B2 materials shall be classed as B3 materials

DIN 4102-1 fire test to building material - Reference Standard
> DIN 4102-2: Fire behaviour of building materials and elements - Building components - Concepts, requirements and tests
> DIN 4102-4: Fire behaviour of building materials and elements - Overview and design of classified building materials, elements and components
> DIN 4102-8: Fire behaviour of building materials and elements - Small-scale test furnace
> DIN 4102-14: Fire behaviour of building materials and elements - Determination of the burning behaviour of floor covering systems using a radiant heat source
> DIN 4102-15: Fire behaviour of building materials and elements - ‘Brandschacht’ apparatus
> DIN 4102-16: Fire behaviour of building materials and elements - ‘Brandschacht’ tests
> DIN 18180: Gypsum plasterboard - Types, requirements and testing
> DIN 50014: Artificial climates in technical applications - Standard atmospheres
> DIN 50050-1: Small cabinets for testing the burning behaviour of materials
> DIN 50051 Burners for testing the burning behaviour of materials
> DIN 50055 Light measuring system for testing smoke development
> DIN 51622 Propane, propene, butane, butene and their mixtures – Requirements
> DIN 51900-2 Determination of gross calorific value of solid and liquid fuels using the bomb calorimeter, and calculation of calorific value - Method using the isothermal
> DIN 51900-3 Determination of gross calorific value of solid and liquid fuels using the bomb calorimeter, and calculation of calorific value - Method using the adiabatic
> DIN 53436-1: Toxicity testing of fire effluents - Combustion apparatus and determination of test temperature
> DIN 53436-2: Toxicity testing of fire effluents - Thermal decomposition method
> DIN 53436-3: Toxicity testing of fire effluents - Method of testing inhalation toxicity
> DIN 53438-1: Determining the response of combustible materials to ignition by a small flame – General
> DIN 66081: Classification of the burning behaviour of textile products - Textile floor coverings
> IS0 1716: 1973 Building materials - Determination of calorific potential
> IS0 4783-2: 1989 Industrial wire screens and woven wire cloth - Guide to the choice of aperture size and wire diameter combinations - Part 2: Preferred combinations for woven wire cloth

DIN 4102-1 fire test to building material-Similar standard
> EN ISO 11925-2: Reaction to fire tests--Ignitability of building products subjected to direct impingement of flame--Part 2: Single-flame source test
> EN 13501-1: Fire classification of construction products and building elements- Part1: Classification using data from reaction to fire tests
> NF P 92 - 501: Safety against fire - Building materials - Reaction to fire tests - Radiation test used for rigid materials. or for materials on rigid substrates (flooring and finishes) of all thicknesses. and for flexible materials thicker that 5 mm
> NF P 92 - 503: Safety against fire - Building materials--Reaction to fire tests. Electrical burner test used for flexible materials
> BS 476: Fire tests on building materials and structures
> GB 8624: Classification for burning behavior of building materials and products
> GB 20286: Requirements and mark on burning behavior of fire retarding products and subassemblies in public place

For more detailed information about Germany Standard DIN 4102-1 fire test to Building Material. Please contact on firetest@firetc.com.

Learn more from www.firetc.net for English or www.firetc.com for Chinese


  Company: Firetc Fire Test Center     [ China ]        
  Contact: Liu
  Tel: 0592-5056213
  Fax: 0592-5105807
  Email: firetest@firetc.com
Disclaimer statement:The information and data included above have been realized by the enterprises and compiled by the staff, and are subject to change without notice to you. The Chemnet makes no warranties or representations whatsoever regarding the facticity, accuracy and validity of such information and data. In order to ensure your interest, we suggest you chose the products posted by our gold suppliers or VIP members.