Fluoroquinolones(meat)Strip Test Kit
Inquiry
Post Date: | Sep 10,2015 |
Expiry Date: | Sep 09,2016 |
Detailed Description: |
Product description
REAGEN™ Fluoroquinolone Strip Test Kit is a qualitative and rapid lateral flow assay designed to detect fluoroquinolone antibiotic residues in meat samples such as chicken and beef .This state-of-the-art test uses a broad-spectrum antibody capable of specifically detecting a range of fluoroquinolone residues. This test is designed for point-of-care use or reference lab settings and eliminates the need for a heating block. The features of the kit are: Rapid extraction method and strip test method – less than 20 minutes High recovery rate of 75%-105% Broad-spectrum antibody that requires no heating step High sensitivity High reproducibility Mechanism of reaction The assay uses a competitive colloidal gold based format.The extracted meat sample (200μL)is added to a clear plastic reaction vessel,and used to resuspend the lyophilized reagents to a uniform pink color in the bottom of the microtiter wells.The sample is incubated briefly(3 min)to allow the fluoroquinolone antibody on the gold particles to engage with any fluoroquinolone antibiotic residues present in the sample.The test strip is then inserted into the sample well with the arrows pointing downward initiating capillary flow up the strip.Any gold particles that are not complexed with antibiotics present in the sample will bind to the fluoroquinolone antibiotic imprinted at the Test line(T-line),forming a signal(red line)at that position.If the fluoroquinolone antibody on the gold particle has engaged with antibiotic present in the sample,the gold particle will flow past the T-line and reach the Control line(C-line).For visual interpretation of the test results,T-line signal intensity that is stronger than the signal at the C-line indicates a negative result.Signal at the T-line which is equal or less intense compared to the C-line indicates the presence of fluoroquinolone antibiotics in the sample.The greater the reduction in signal intensity at the T-line,the greater the concentration of fluoroquinolone antibiotic residues present in the sample. |
Company: | REAGEN LLC [ United States ] |
Contact: | nicole |
Tel: | 8566711789 |
Fax: | 8568585434 |
Email: | reagenllc@gmail.com |
-
Disclaimer statement:The information and data included above have been realized by the enterprises and compiled by the staff, and are subject to change without notice to you. The Chemnet makes no warranties or representations whatsoever regarding the facticity, accuracy and validity of such information and data. In order to ensure your interest, we suggest you chose the products posted by our gold suppliers or VIP members.