Home > Offer to Sell > Petrochemicals > Fuel Oil > V-Sorb 4800 BET surface area and pore size distribution analysis intrument

V-Sorb 4800 BET surface area and pore size distribution analysis intrument

Inquiry
  Post Date: Oct 23,2015
  Expiry Date: Oct 22,2016
  Detailed Description: Price:9999 USD Metric Tons
V-Sorb 4800P specific surface area and pore size analyzer Introduction

V-Sorb 4800P researched from Gold APP Instruments experts for surface area and pore size determination with using of static volumetric principle. Multi pioneered techs heighten accuracy and consistence of results, enhance measurement stability, all these lead to a leading level among world technology. It designed from the user perspective and equipped with fully automated operation, user-friendly interface makes it easy to learn, imported accessories assure stability and prolong life. Perfect design, sophisticated production and strict testing guarantee to meet customers’ real demands. The high cost performance of V-Sorb 4800P easily ensure your investment profits and flexible equipped peripheral can satisfy different users’ requests.


V-Sorb 4800P specific surface area and pore size analyzer parameters

Analysis Method: static volumetric nitrogen adsorption
Versatility: Adsorption and desorption isotherms, Single and multi-point BET surface area analysis, T-plot external surface area, True density analysis, BJH pore size, BJH total pore volume and porosity, T-plot micropore analysis, MP micropore, Langmuir surface area, Horvath-Kawazoe (HK) micropore, Saito-Foley (SF) micropore, Dubinin-Astakhov (DA) micropore, Dubinin-Radushkevich (DR) micropore, carbon black (STSA) etc.
Measuring Ranges: 0.01m2/g to no known upper limit (surface area); 0.35 to 500nm (pore size)
Accuracy: repeatability errors ≤1%
Vacuum System: V-Sorb unique monolithic manifolds and solenoid valve control system, greatly reduce the dead volume; improve the adsorbate micro-change sensitivity; enhance pore size distribution analysis resolution; decrease connecting points; strengthen sealing performance and prolonged instrument life
Coolant Level Prober: V-Sorb original coolant level control system with temperature probe, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change
Control System: programmable solenoid valve system with high integration and strong anti-interference ability, enhance instrument’s stability
Sample Ports: four samples’ analyzing and four samples’ degassing concurrently
Pressure Measurement: imported sectional measuring dual pressure transducer, notably improve the measuring accuracy at low P/Po point, 0-1000Torr (0-133Kpa), 0-10Torr (0-1.33Kpa)
Transducer Accuracy: imported silicon thin film pressure transducer, accuracy can reach 0.1% of real reading, better than 0.1% of F.S.(full-scale), far accurate than Pirani resistance vacuum gauge(general error is 10%-15%)
Partial Pressure: P/Po controllable accuracy range is 5x10-6-0.998
Ultimate Vacuum: 4x10-2Pa (3x10-4Torr)
Vacuum Pump: built-in bipolar vacuum pump controlled by patented software which can auto control pump’s start/stop
Sample Types: powders, particle, fiber, flakes and other materials
Adsorbate Gas: high purity nitrogen (≥99.999%), Ar, Kr, CO2, CO, C4H10 etc. non-corrosive gases are optional
Data Acquisition: high-precision and high integration data acquisition modules, minimal error, strong anti-interference ability
Data Reduction: Windows®-based independent developed Gold APP softwareTM, perfect versatility, produced full featured and multi-model reports
Specifications: Height 22.05 inches (56cm)* Width 20.87 inches (53cm)*Depth 23.62 inches (60cm); 132 pound (60kg)


V-Sorb 4800P specific surface area and pore size analyzer features

A: Vacuum System
1. Unique integral manifolds system, decrease connecting points apparently, reduce leak rate, improve ultimate vacuum.
2. Modularity design can configure as customer requests, benefits future functions extension and instrument maintenance.
3. Germany imported bipolar vacuum pump, low noise, stable working, oil-return prevention; ultimate vacuum can reach 4x10-2Pa (3x10-4Torr).

B: Control System
1. Industry used programmable solenoid valve system, strong anti-interference ability, convenient for installation and uninstallation.
2. Separated analysis and treatment manifolds can prevent foreign matter to contaminate manifolds in sample treatment.

C. Measures for Improving Accuracy
1. Imported silicon thin film capacitive pressure transducer, accuracy can reach 0.1% of real reading, better than 0.1% of F.S. (full-scale).
2. 0-10Torr (optional) and 0-1000Torr dual pressure transducers, sectional measurement in pressure range can reduce errors in low vacuum, 0-10Torr silicon thin film transducer is highly accurate than Pirani resistance vacuum gauge (general error is 10%-15%).
3. Unique monolithic manifolds system, decrease connecting points and reduce leak rate apparently.
4. Original stepping coolant level control system, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change.
5. Pioneered gas outlet and inlet control system can efficiently prevent sample splash in evacuation and gas inlet process, guarantee clean manifolds and sample weight unchanged, avoid zero and liner drifting caused by transducer’s macro-change.

D. Data Acquisition and Reduction
1. High precision and integration data acquisition module is easy to connect, minimal errors and strong anti-interference ability; standard 485 communication mode is good for analyzer’s applications extension and interconnection, can also conveniently switched to RS232 and USB modes.
2. Multi calculating methods for data reduction provides all-round sample analysis options; powerful data archiving and searching system helps a lot for data management.


V-Sorb 4800P specific surface area and pore size analyzer application

1. Super micro powder, nanomaterials, particle and fiber shaped specific surface area analysis.
2. Product quality control for powder materials related corporations.
3. Research institutes, universities for BET theory teaching.
4. Full cells, catalysts, additives, adsorbent, ceramics, magnetic materials, energy storage materials etc.
5. Other researches concern surface area performance.

Contact info:
Web: www.jinaipu.com/ www.app-one.com.cn
Email: sales@jinaipu.com
Tel.: 0086-10-82133318 Ext.810
Fax: 0086-10-82118197
Mobile: 0086-18210009838
IMs:
Skypi: Gold-APP-Instruments
Yahoo: goldappinstruments@ymail.com
Gtalk: goldappinstruments2008@gmail.com




  Company: Gold APP Instruments Corp. China     [ China ]        
  Contact: Andy Hoa
  Tel: 18210009838
  Fax: 861082118197
  Email: langlang.hao@jinaipu.com
Disclaimer statement:The information and data included above have been realized by the enterprises and compiled by the staff, and are subject to change without notice to you. The Chemnet makes no warranties or representations whatsoever regarding the facticity, accuracy and validity of such information and data. In order to ensure your interest, we suggest you chose the products posted by our gold suppliers or VIP members.