WMS-500 Fetal Monitor
Inquiry
Post Date: | May 23,2014 |
Expiry Date: | May 23,2015 |
Detailed Description: |
Payment Method: T/T in advance Features: Single or Twins Ultrasound transducer Data Graph and Trend Table Review of both mother and fetal Built-in thermal printer Built-in Network capability for connect with central monitoring software Programmable alarms All the colors and looks or the parameters can be customsized Multi-face views, select focus on mother or fetal Storage of patient information and data Performance Specifications: Display:8.4" Color TFT Resolution:640x480 Display Mode:Standard View,Fetal View,Mother View Indicator:Power indicator light, Alarm sound Interface:Socket for connecting fetals FHR, TOCO, and Fetal Movement sensorSocket for connecting mothers ECG, NIBP and SPO2 sensor.Net Socket(RJ45) for communication cable with Central Monitoring Station Sofrware. Power Supply:AC 100 ~ 240V, 50/60Hz, Powe < 60VA Trend Graph:Resolution from 1s, 5s, 10s. Maximum time 96 hours. Trend Table:Resolution from 1s, 5s, 10s. Review up to 1000 items. Alarm:Ajustable High and Low limits. Three level audible and vistual alarm. User Configuration:All the color of parameters and waves can be set according to users willing. Technical specifications: Safety Meet the requirment of IEC60601 series Type of Protection:Class II with internal electirc power supply Degree of Protection:BF Dimention and Weight Dimention:92(W)x82(H)x22(D)mm Weight:136g(with battery) Operation Environment: Temperature:0℃~ +40℃ Humidity:15% ~ 95% Storage Environment: Temperature:-20℃~ +60℃ Humidity:10% ~ 95% Patient Range:Pregnant Adult FHR: Ultrasound Frequency:2MHz Range:50 ~ 210 bpm Resolution:1bmp Accuracy:±2bmp TOCO: Range:0 ~ 100% Resolution:1% Non-linear Error:<=±8% Zero control:Manual FETAL MOVEMENT: Manual fetal movement mark SPO2: Measurement Range:0 ~ 100% Resolution:1% Accuracy:±2%(70%~100%, Adult/Pediatric, non-motion) ±3%(70%~100%, Neonate, non-motion)0% ~ 69% unspecified Alarm Range:0% ~ 100% Refreshing Rate:1s Pulse Rate: Measurement Range:25 ~ 250 bpm Resolution:1bpm Accuracy:±3 bpm (non-motion) Alarm Range:25 ~ 250 bmp Refreshing Rate:1s ECG: Lead mode:3-lead or 5-lead Lead selection:I, II, III, AVR, AVL, AVF, V HR range:15 ~ 300 bpm ECG Waveform:2 channals Accuracy:±2bpm or ±2%, which is greater S-T segment detection range: -2.0mv ~ +2.0mv Arrhythmia analysis: 13 kinds of arrhythmia Alarm Range:15 ~ 300 bpm NIBP: Method:Oscillometry Mode:Manual/Auto/Contiuous Measurement Range:25 ~ 260mmHg Atuo Measure Interval: 5, 10, 15, 30, 45, 60, 90 minutes Resolution:1mmHg Overpressure Protection: 300mmHg Alarm range:25 ~260mmHg |
Company: | Wkea Med Supplies Corp. [ China ] |
Contact: | grace |
Tel: | 86-431-81912110 |
Fax: | |
Email: | grace.jiang@wkeamedsupplies.com |
-
Disclaimer statement:The information and data included above have been realized by the enterprises and compiled by the staff, and are subject to change without notice to you. The Chemnet makes no warranties or representations whatsoever regarding the facticity, accuracy and validity of such information and data. In order to ensure your interest, we suggest you chose the products posted by our gold suppliers or VIP members.