BS 476-20 fire test to Building Material BS476-20
-
Post Date:
Aug 01,2014
-
Expiry Date:
Aug 01,2015
-
Detailed Description:
BS 476-20 fire test to Building Material BS476-20
Firetc fire test center will provide British Standard BS 476-20 Fire test to Building Material
For more detailed information about BS 476-20,
Please see: http://www.firetc.net/firetesting/show.php?itemid=673
BS 476-20 Fire Resistance Test to Building Material – Standard
Fire Tests on Building materials and structures – Part 20. Method of test for determination of the fire resistance of elements of construction (General principles)
BS 476-20 Fire Resistance Test to Building Material – Standard Brief
The objective of determining fire resistance, as described in the part and the associated parts of BS 476, is to assess the behaviour of a specimen of an element of building construction when subjected to defined heating and pressure conditions. The method provides a means of quantifying the ability of an element to withstand exposure to high temperatures, by setting criteria by which the loadbearing capacity, the fire containment (integrity) and the thermal transmittance (insulation) functions can be adjudged.
A representative sample of the elements is exposed to a specified regime of heating and the performance of the test sample is monitored on the basis of criteria described in the standard. Fire resistance of the test elements is expressed as the time for which the appropriate criteria have been satisfied. The times so obtained are a measure of the adequacy of the construction in a fire but have no direct relationship with the duration of a real fire.
BS 476-20 describes a procedure for a laboratory test for the determination of fire resistance of elements of construction.
BS 476-20 Fire Resistance Test to Building Material – Relative Standard
BS 476:Fire tests on building materials and structures
BS 476-3:Fire tests on building materials and structures. Classification and method of test for external fire exposure to roofs
BS 476-4:Fire tests on building materials and structures - Part 4: Non-combustibility test for materials
BS 476-5:Fire Tests on Building Materials and Structures Part 5: Method of Test for Ignitability
BS 476-6:Fire tests on building materials and structures — Part 6: Method of test for fire propagation for products
BS 476-7:Fire Tests on Building Materials and Structures Part 7: Method of Test to Determine the Classification of the Surface Spread of Flame of Products
BS 476-11:Fire tests on building materials and structures — Part 11: Method for assessing the heat emission from building materials
BS 476-12:Fire tests on building materials and structures — Part 12: Method of test for ignitability of products by direct flame impingement
BS 476-13:Fire Tests on Building Materials and Structures Part 13: Method of Measuring the Ignitability of Products Subjected to Thermal Irradiance
BS 476-15:Fire Tests on Building Materials and Structures Part 15: Method of Measuring the Rate of Heat Release of Products
BS 476-20:Fire Tests on Building Materials and Structures Part 20: Method for Determination of the Fire Resistance of Elements of Construction (General Principles)
BS 476-21:Fire Tests on Building Materials and Structures Part 21: Methods for Determination of the Fire Resistance of Load bearing Elements of Construction
BS 476-22:Fire Tests on Building Materials and Structures Part 22: Methods for Determination of the Fire Resistance of Non- Load bearing Elements of Construction
BS 476-23:Fire Tests on Building Materials and Structures Part 23: Methods for Determination of the Contribution of Components to the Fire Resistance of a Structure
BS 476-24:Fire Tests on Building Materials and Structures Part 24: Method for Determination of the Fire Resistance of Ventilation Ducts
For more detailed information about British Standard BS 476-20 fire test to Fire test to Building Material. Please contact on firetest@firetc.com.
Learn more from www.firetc.net for English or www.firetc.com for Chinese
-
Company:
Firetc Fire Test Center
[ China ]
-
Contact:
Liu
-
Tel:
0592-5056213
-
Fax:
0592-5105807
-
Email:
firetest@firetc.com
Inquiry